SMC - Air Dryers
Air Dryers
มีทั้งหมด 13 รุ่น คือ
- Refrigerated Air Dryer IDF
- Refrigerated Air Dryer IDF □E / F / D
- Refrigerated Air Dryer IDU □E
- Refrigerated Air Dryer/Double Energy Saving Function Series IDF 100FS / 125FS / 150FS
- Refrigerated Air Dryer/For Use in Southeast Asia IDFC□
- Refrigerated Air Dryer/For Use in Europe, Asia and Oceania IDFA
- Refrigerated Air Dryer/For Use in Europe, Asia, and Oceania IDFA□E/F
1) Refrigerated Air Dryer IDF

Features | Refrigerated Air Dryer IDF
- Applicable for the high-temperature environments
- Ambient temperature : Max. 45℃
- Inlet air temperature : Max. 65℃
- Increased air flow capacity
Specifications | Refrigerated Air Dryer IDF
Series | Rated inlet condition | Air flow capacity (m3/min[ANR]) 50 Hz | Air flow capacity (m3/min[ANR]) 60 Hz | Refrigerant | Port size |
---|---|---|---|---|---|
IDF60 | 35℃ 0.7 MPa |
5.6 | 6.5 | R410A (HFC) GWP: 2088 |
R1 |
IDF70 | 35℃ 0.7 MPa |
8 | 9.1 | R410A (HFC) GWP: 2088 |
R1 1/2 |
IDF80 | 40℃ 0.7 MPa |
11.6 | 13.6 | R410A (HFC) GWP: 2088 |
R2 |
IDF90 | 40℃ 0.7 MPa |
14.3 | 16.4 | R410A (HFC) GWP: 2088 |
R2 |
2) Refrigerated Air Dryer IDF □E / F / D

Features | Refrigerated Air Dryer IDF
- Large size series
- Tolerant of high temperature environment!
- Top of its class in the industry for the large air-cooled type
- Ambient temperature 45°C/Inlet
- Air temperature 60°C (IDF100F to 150F)
- Energy saving design
Specifications | Refrigerated Air Dryer IDF
Series | Rated inlet condition | Air flow capacity (m3/min[ANR]) 50 Hz | Air flow capacity (m3/min[ANR]) 60 Hz | Applicable air compressor (kW) | Refrigerant | Port size |
---|---|---|---|---|---|---|
IDF1E | 35℃ 0.7 MPa |
0.1 | 0.12 | 0.75 | R134a (HFC) |
Rc3/8 |
IDF2E | 35℃ 0.7 MPa |
0.2 | 0.235 | 1.5 | R134a (HFC) |
Rc3/8 |
IDF3E | 35℃ 0.7 MPa |
0.32 | 0.37 | 2.2 | R134a (HFC) |
Rc3/8 |
IDF4E | 35℃ 0.7 MPa |
0.52 | 0.57 | 3.7 | R134a (HFC) |
Rc1/2 |
IDF6E | 35℃ 0.7 MPa |
0.75 | 0.82 | 5.5 | R134a (HFC) |
Rc3/4 |
IDF8E | 35℃ 0.7 MPa |
1.22 | 1.32 | 7.5 | R134a (HFC) |
Rc3/4 |
IDF11E | 35℃ 0.7 MPa |
1.65 | 1.82 | 11 | R134a (HFC) |
Rc3/4 |
IDF15E1 | 35℃ 0.7 MPa |
2.8 | 3.1 | 15 | R134a (HFC) |
Rc1 |
IDF22E | 35℃ 0.7 MPa |
3.9 | 4.3 | 22 | R407C (HFC) |
R1 |
IDF37E | 35℃ 0.7 MPa |
5.7 | 6.1 | 37 | R407C (HFC) |
R1 1/2 |
IDF55E | 40℃ 0.7 MPa |
8.4 | 9.8 | 55 | R407C (HFC) |
R2 |
IDF75E | 40℃ 0.7 MPa |
11.0 | 12.4 | 75 | R407C (HFC) |
R2 |
IDF100F | 40℃ 0.7 MPa |
16.0 | 18.8 | 100 | R407C (HFC) |
R2 |
IDF125F | 40℃ 0.7 MPa |
20.1 | 23.7 | 125 | R407C (HFC) |
65 (2 1/2B) flange |
IDF150F | 40℃ 0.7 MPa |
25.0 | 30.0 | 150 | R407C (HFC) |
80 (3B) flange |
IDF190D | 40℃ 0.7 MPa |
32.0 | 38.0 | 190 | R407C (HFC) |
80 (3B) flange |
IDF240D | 40℃ 0.7 MPa |
43.0 | 50.0 | 240 | R407C (HFC) |
100 (4B) flange |
IDF370D | 35℃ 0.7 MPa |
54.0 | 65.0 | 370 | R407C (HFC) |
150 (6B) flange |
3) Refrigerated Air Dryer IDU □E

Features | Refrigerated Air Dryer IDU □E
- Air flow capacity: Increased by up to 40% (SMC comparison)
- Power consumption: Reduced by up to 40% (SMC comparison)
Specifications | Refrigerated Air Dryer IDU □E
Series | Rated inlet condition | Air flow capacity (m3/min[ANR]) 50 Hz | Air flow capacity (m3/min[ANR]) 60 Hz | Applicable air compressor (kW) | Refrigerant | Port size |
---|---|---|---|---|---|---|
IDU3E | 55℃ 0.7 MPa |
0.32 | 0.37 | 2.2 | R134a (HFC) |
Rc3/8 |
IDU4E | 55℃ 0.7 MPa |
0.52 | 0.57 | 3.7 | R134a (HFC) |
Rc1/2 |
IDU6E | 55℃ 0.7 MPa |
0.75 | 0.82 | 5.5 | R134a (HFC) |
Rc3/4 |
IDU8E | 55℃ 0.7 MPa |
1.1 | 1.2 | 7.5 | R134a (HFC) |
Rc3/4 |
IDU11E | 55℃ 0.7 MPa |
1.5 | 1.7 | 11 | R134a (HFC) |
Rc3/4 |
IDU15E1 | 55℃ 0.7 MPa |
2.6 | 2.8 | 15 | R134a (HFC) |
Rc1 |
IDU22E | 55℃ 0.7 MPa |
3.9 | 4.3 | 22 | R407C (HFC) |
R1 |
IDU37E | 55℃ 0.7 MPa |
5.7 | 6.1 | 37 | R407C (HFC) |
R1 1/2 |
IDU55E | 55℃ 0.7 MPa |
8.4 | 9.8 | 55 | R407C (HFC) |
R2 |
IDU75E | 55℃ 0.7 MPa |
11.0 | 12.5 | 75 | R407C (HFC) |
R2 |
4) Refrigerated Air Dryer/Double Energy Saving Function Series IDF 100FS / 125FS / 150FS

Features | Refrigerated Air Dryer/Double Energy Saving Function Series IDF 100FS / 125FS / 150FS
- Energy-saving design (Second re-heater + Digital scroll compressor)
- Power consumption: Reduced by up to 76%
- Exhaust heat: Reduced by up to 25%
- Tolerant of high temperature environments!
- Ambient temperature: Up to 45ºC, Inlet air temperature: Up to 60ºC
Specifications | Refrigerated Air Dryer/Double Energy Saving Function Series IDF 100FS / 125FS / 150FS
Series | Applicable compressor (kW) | Air flow capacity (m3/min[ANR]) 50 Hz | Air flow capacity (m3/min[ANR]) 60 Hz |
---|---|---|---|
IDF100FS | 100 | 16 | 18.8 |
IDF125FS | 125 | 20.1 | 23.7 |
IDF150FS | 150 | 25 | 27 |
5) Refrigerated Air Dryer/For Use in Southeast Asia IDFC□

Features | Refrigerated Air Dryer/For Use in Southeast Asia IDFC□
- Applicable for the high-temperature environments of tropical regions
- Can be used in high-temperature environments
- Ambient temperature : Max. 45℃
- Inlet air temperature : Max. 65℃
- Dew point range : 3℃ to 20℃
- Air flow capacity : 9.2 m3 / min (52% increase compared to the current model)
- Power supply voltage : Single-phase 230 VAC (50 Hz)
Specifications | Refrigerated Air Dryer/For Use in Southeast Asia IDFC□
Series | Rated inlet condition | Air flow capacity (m3/min [ANR]) Outlet air pressure dew point 3℃ | Air flow capacity (m3/min [ANR]) Outlet air pressure dew point 10℃ | Air flow capacity (m3/min [ANR]) Outlet air pressure dew point 20℃ | Refrigerant | Port size |
---|---|---|---|---|---|---|
IDFC60 | 50℃ 0.7 MPa |
0.9 | 2.8 | 4.7 | R410A(HFC) GWP: 2088 |
R1 |
IDFC70 | 50℃ 0.7 MPa |
1.6 | 4.7 | 7.8 | R410A(HFC) GWP: 2088 |
R1 1/2 |
IDFC80 | 50℃ 0.7 MPa |
2.2 | 6.5 | 10.9 | R410A(HFC) GWP: 2088 |
R2 |
IDFC90 | 50℃ 0.7 MPa |
3.1 | 9.2 | 15.4 | R410A(HFC) GWP: 2088 |
R2 |
6) Refrigerated Air Dryer/For Use in Europe, Asia and Oceania IDFA

Features | Refrigerated Air Dryer/For Use in Europe, Asia and Oceania IDFA
- Applicable for the high-temperature environments
- Ambient temperature : Max. 45℃
- Inlet air temperature : Max. 65℃
- Increased air flow capacity
- Power supply voltage: Single-phase 230 VAC (50 Hz)
Specifications | Refrigerated Air Dryer/For Use in Europe, Asia and Oceania IDFA
Series | Rated inlet condition | Air flow capacity (m3/h [ANR] ) Dew point 3℃ | Air flow capacity (m3/h [ANR] ) Dew point 7℃ | Air flow capacity (m3/h [ANR] ) Dew point 10℃ | Refrigerant | Port size |
---|---|---|---|---|---|---|
IDFA60 | 35℃ 0.7 MPa |
204 | 300 | 360 | R410A(HFC) GWP:2088 |
R1 |
IDFA70 | 35℃ 0.7 MPa |
312 | 408 | 480 | R410A(HFC) GWP:2088 |
R1 1/2 |
IDFA80 | 35℃ 0.7 MPa |
552 | 654 | 720 | R410A(HFC) GWP:2088 |
R2 |
IDFA90 | 35℃ 0.7 MPa |
810 | 900 | 960 | R410A(HFC) GWP:2088 |
R2 |
7) Refrigerated Air Dryer/For Use in Europe, Asia, and Oceania IDFA□E/F

Features | Refrigerated Air Dryer/For Use in Europe, Asia, and Oceania IDFA□E/F
- EC Directive compliant product (With CE mark)
- Power supply voltage: Single-phase 230 VAC (50 Hz)
Specifications | Refrigerated Air Dryer/For Use in Europe, Asia, and Oceania IDFA□E/F
Series | Rated inlet condition | Air flow capacity (m3/h [ANR]) Outlet air pressure dew point 3℃ | Air flow capacity (m3/h [ANR]) Outlet air pressure dew point 7℃ | Air flow capacity (m3/h [ANR]) Outlet air pressure dew point 10℃ | Refrigerant | Port size |
---|---|---|---|---|---|---|
IDFA3E | 35℃ 0.7 MPa |
12 | 15 | 17 | R134a (HFC) |
Rc3/8 |
IDFA4E | 35℃ 0.7 MPa |
24 | 31 | 34 | R134a (HFC) |
Rc1/2 |
IDFA6E | 35℃ 0.7 MPa |
36 | 46 | 50 | R134a (HFC) |
Rc3/4 |
IDFA8E | 35℃ 0.7 MPa |
65 | 83 | 91 | R134a (HFC) |
Rc3/4 |
IDFA11E | 35℃ 0.7 MPa |
80 | 101 | 112 | R134a (HFC) |
Rc3/4 |
IDFA15E | 35℃ 0.7 MPa |
120 | 152 | 168 | R134a (HFC) |
Rc1 |
IDFA22E | 35℃ 0.7 MPa |
182 | 231 | 254 | R407C (HFC) |
R1 |
IDFA37E | 35℃ 0.7 MPa |
273 | 347 | 382 | R407C (HFC) |
R1 1/2 |
IDFA55E | 35℃ 0.7 MPa |
390 | 432 | 510 | R407C (HFC) |
R2 |
IDFA75E | 35℃ 0.7 MPa |
660 | 720 | 822 | R407C (HFC) |
R2 |
IDFA100F-38 | 40℃ 0.7 MPa |
- | - | 960 | R407C (HFC) |
R2 |
IDFA125F-38 | 40℃ 0.7 MPa |
- | - | 1210 | R407C (HFC) |
R2 1/2 |
IDFA150F-38 | 40℃ 0.7 MPa |
- | - | 1500 | R407C (HFC) |
DIN flange 80 |
IDFA100F-40 | 35℃ 0.7 MPa |
860 | - | - | R407C (HFC) |
R2 |
IDFA125F-40 | 35℃ 0.7 MPa |
1100 | - | - | R407C (HFC) |
R2 1/2 |
IDFA150F-40 | 35℃ 0.7 MPa |
1340 | - | - | R407C (HFC) |
DIN flange 80 |
8) Refrigerated Air Dryer/For Use in North, Central and South America IDFB

Features | Refrigerated Air Dryer/For Use in North, Central and South America IDFB
- Applicable for the high-temperature environments
- Ambient temperature : Max. 113ºF (45ºC)
- Inlet air temperature : Max. 149ºF (65ºC)
- Increased air flow capacity
- Power supply voltage: Single-phase 230 VAC (60 Hz)
Specifications | Refrigerated Air Dryer/For Use in North, Central and South America IDFB
Series | Rated inlet condition | Air flow capacity (m3/h [ANR] ) Dew point 37ºF (2.8℃) | Air flow capacity (m3/h [ANR]) Dew point 45ºF (7.2℃) | Air flow capacity (m3/h [ANR]) Dew point 50ºF (10℃) | Refrigerant | Port size |
---|---|---|---|---|---|---|
IDFB60 | 100ºF (37.8℃) 100 psi (0.7 MPa) |
113 (192) |
155 (264) |
177 (300) |
R410A (HFC) GWP: 2088 |
R1, NPT1 |
IDFB70 | 100ºF (37.8℃) 100 psi (0.7 MPa) |
166 (282) |
215 (366) |
251 (426) |
R410A (HFC) GWP: 2088 |
R1 1/2, NPT1 1/2 |
IDFB80 | 100ºF (37.8℃) 100 psi (0.7 MPa) |
247 (420) |
314 (534) |
353 (600) |
R410A (HFC) GWP: 2088 |
R2, NPT2 |
IDFB90 | 100ºF (37.8℃) 100 psi (0.7 MPa) |
335 (570) |
406 (690) |
459 (780) |
R410A (HFC) GWP: 2088 |
R2, NPT2 |
9) Refrigerated Air Dryer/For Use in North, Central, and South America IDFB□E

Features | Refrigerated Air Dryer/For Use in North, Central, and South America IDFB□E
- UL, CSA certified product
- Power supply voltage: Single-phase 115 VAC (60 Hz), 230 VAC (60 Hz) 3-phase 460 VAC (60 Hz)
Specifications | Refrigerated Air Dryer/For Use in North, Central, and South America IDFB□E
Series | Rated inlet condition | Air flow capacity SCFM (m3/h [ANR] ) Outlet air pressure dew point Note) 37ºF (2.8℃) | Air flow capacity SCFM (m3/h [ANR] ) Outlet air pressure dew point Note) 45ºF (7.2℃) | Air flow capacity SCFM (m3/h [ANR] ) Outlet air pressure dew point Note) 50ºF (10℃) | Refrigerant | Port size |
---|---|---|---|---|---|---|
IDFB3E: | 100ºF (37.8℃) 100 psi (0.7 MPa): |
10(17): | 11(19): | 12(20): | R134a (HFC): |
NPT3/8: |
IDFB4E: | 100ºF (37.8℃) 100 psi (0.7 MPa): |
15(25): | 16(27): | 17(28): | R134a (HFC): |
NPT1/2: |
IDFB6E: | 100ºF (37.8℃) 100 psi (0.7 MPa): |
25(43): | 26(45): | 28(47): | R134a (HFC): |
NPT3/4: |
IDFB8E: | 100ºF (37.8℃) 100 psi (0.7 MPa): |
41(70): | 43(74): | 45(77): | R134a (HFC): |
NPT3/4: |
IDFB11E: | 100ºF (37.8℃) 100 psi (0.7 MPa): |
59(100): | 62(106): | 65(110): | R134a (HFC): |
NPT3/4: |
IDFB15E: | 100ºF (37.8℃) 100 psi (0.7 MPa): |
71(120): | 80(136): | 86(147): | R134a (HFC): |
NPT1: |
IDFB22E: | 100ºF (37.8℃) 100 psi (0.7 MPa): |
107(182): | 120(205): | 130(221): | R134a (HFC): |
NPT1: |
IDFB37E: | 100ºF (37.8℃) 100 psi (0.7 MPa): |
161(273): | 173(294): | 181(308): | R134a (HFC): |
NPT1 1/2: |
IDFB55E: | 100ºF (37.8℃) 100 psi (0.7 MPa): |
226(384): | 258(438): | 297(504): | R407C (HFC): |
NPT2: |
IDFB75E: | 100ºF (37.8℃) 100 psi (0.7 MPa): |
300(510): | 353(600): | 406(690): | R407C (HFC): |
NPT2: |
10) Thermo-dryer with Air Temperature Adjustment Function IDH□

Features | Thermo-dryer with Air Temperature Adjustment Function IDH□
- Stable supply of temperature and pressure controlled dry clean air Can supply compressed air with same conditions and quality regradless of the season
- Application example: Supplying compressed air with constant conditions to air bearings mounted on a tool
- Built-in filter Nominal filtration: 0.01 μm (99.9% filtration efficiency) Outlet oil mist concentration: Max. 0.01 mg/m3 (ANR) Outlet cleanliness: Particles of 0.3 μm or more: 3.5 particles/L (ANR) or less
- Compatible with power supplies from around the world Single phase 100, 200, 230 VAC (50/60 Hz)
Specifications | Thermo-dryer with Air Temperature Adjustment Function IDH□
Series | Air flow capacity L/min(ANR) | Outlet air temperature adjustment range | Outlet air set pressure range | Outlet air temperature stability | Cooling method |
---|---|---|---|---|---|
IDH□4 | 100 to 500 | 15 to 30℃ | 0.15 to 0.85 MPa | ±0.1 | Heater operation PID control |
IDH□6 | 200 to 800 | 15 to 30℃ | 0.15 to 0.85 MPa | ±0.1 | Heater operation PID control |
11) Heatless Air Dryer ID

Features | Heatless Air Dryer ID
- Can supply dry air with a low dew point below –30ºC
- Compact and lightweight without a heater or an electric control board
- It is possible to check the outlet dew point with the indicator. (Self-regenerative type allows for easy maintenance)
Specifications | Heatless Air Dryer ID
Series | Outlet flow L/min (ANR) | Inlet flow L/min (ANR) |
---|---|---|
ID | 80 to 780 | 100 to 975 |
12) Membrane Air Dryer IDG□A / IDG

Features | Heatless Air Dryer ID
- It is possible to easily supply dry air using the hollow fiber membrane.
- Non-fluorocarbon
- Power supply not required
- Compatible with low dew points (–60ºC)
- No vibration or heat discharge
- With a dew point indicator
Specifications | Heatless Air Dryer ID
Series | Outlet flow L/min (ANR) | Inlet flow L/min (ANR) |
---|---|---|
IDG□A/IDG | 10 to 1000 | -15, -20, -40, -60 |
13) Moisture Control Tube IDK

Features | Moisture Control Tube IDK
- Prevents condensation in piping for small cylinders / air grippers
- Diffuses water vapor in the piping to the outside
- All you have to do is install the moisture control tube. Additional power supplies and works are not necessary.
Specifications | Moisture Control Tube IDK
Series | O.D./I.D. (mm) | Effective length (mm) | Applicable fittings |
---|---|---|---|
IDK02 Linear shape |
2/1.2 | 100 200 |
KQ2 |
IDK04 Linear shape |
4/2.5 | 100 200 |
KQ2 |
IDK06 Linear shape |
6/4 | 100 200 |
KQ2 |
IDK04-100-C1 Coil shape |
4/2.5 | 100 | KQ2 |