AirTAC - วาล์วควบคุมทิศทางการไหลด้วยลม EAV ISO Standard Series
วาล์วควบคุมทิศทางการไหลด้วยลม EAV ISO Standard Series
Download PDF: Pneumatic Control valve EAV ISO seriesFeatures | AirTAC วาล์วควบคุมทิศทางการไหลด้วยลม EAV ISO Standard Series
วาล์วควบคุมทิศทางการไหลด้วยลม แบบ ISO ชนิด 5/2, 5/3 ทางรุ่น EAV ISO Standard (EAV ISO Standard Series)
- Succinct appearance and compact conformation.
- The installation size conforms to ISO 5599/1 standard.
- Because of the special seals, the features are large flow rate and long lifetime.
- External pilot, can be used without electrical.
- You need install the valve together with the sub-base. There are individual and manifold sub-base.
- There are various connection and installation method for manifold.lt is easy to use.
- The manifold of 200/300/400 series have the function of exhaust throttling, so no need to connect another throttle valve.
- Because of be used external pilot, the working pressure of double air control valve can be zero or vacuum.
สัญลักษณ์ (Symbol) | AirTAC วาล์วควบคุมทิศทางการไหลด้วยลม EAV ISO Standard Series
Specifications | AirTAC วาล์วควบคุมทิศทางการไหลด้วยลม EAV ISO Standard Series
Item | Specification | ||||
---|---|---|---|---|---|
Model | 200 Series | 300 Series | 400 Series | 600 Series | |
Fluid | Air (to be filtered by 40µm filter elemaent) | ||||
Acting | External pilot | ||||
Lubriaction (1) | Not required | ||||
Operating Pressure | Single air control | 0.2~1.0 MPa (29~145 psi) | |||
Double air control | -0.09~1.0 MPa (-13~145 psi) | ||||
Control pressure (External pilot) | 0.2~1.0 MPa (29~145psi) | ||||
Proof pressure | 1.5 MPa (215psi) | ||||
Temperature | -20 ~70 °C | ||||
Port size (manifold) (2) | 1/4" | 3/8" | 1/2" | 3/4" | |
Port size (end plate) | 3/8" | 1/2" | 3/4" | 1" | |
Installation size | ISO 5599-1 standard |
- Onec lubricated air is used, continue with same medium to optimise valve kife span. Lubricants like ISO VG32 or equivalent are recommended.
- PT thread and G thread are available.
Ordering code | AirTAC วาล์วควบคุมทิศทางการไหลด้วยลม EAV ISO Standard Series
Ordering code of valve
Example: EAV210
How to Select: EAV(1) 2(2) 10(3)
Number | Code | Description |
---|---|---|
(1) | ESV | EAV: ISO standard solenoid valve |
(2) | 2 | 200 series |
3 | 300 series | |
4 | 400 series | |
6 | 600 series | |
(3) | 10 | Single air control 5/2 way |
20 | Double air control 5/2 way | |
30C | Double air control 5/2 closed center | |
30E | Double air control 5/2 way exhaust center | |
30E | Double air control 5/2 way pressure center |
Ordering code for manifold
Example: ESV201MG
How to Select: ESV(1) 20(2) 1M(3) G(4) [ ](5) [ ](6)
Number | Code | Description |
---|---|---|
(1) | ESV | EAV: ISO standard solenoid valve |
(2) | 2 | 200 series |
3 | 300 series | |
4 | 400 series | |
6 | 600 series | |
(3) | 1M | |
2M | ||
3M | ||
4M | ||
(4) | P | PT |
G | G | |
(5) | 1M | Blank: Individual pilot port |
2M | Blank: Individual pilot port W: Centralized pilot port |
|
(6) | 1M | Blank: Side port |
B: Bottom port | ||
2M | Blank: Lift side port | |
R: Right side port | ||
B: Bottom Port | ||
4M | Blank: Left side port |
Ordering code for accessories
Example: PESV200MR2
How to Select: P(1) 100M(2) R2(3)
Accessoris code (1) | Code (2) | Accessories type (3) |
---|---|---|
P: Unit accessories | ESV200M: 200 Series manifold | R2: Blanking plate |
ESV300M: 300 series manifolld | ||
ESV400M: 400 series maniflod | ||
ESV600M: 600 series maniflod |
Inner structures | AirTAC วาล์วควบคุมทิศทางการไหลด้วยลม EAV ISO Standard Series
No. | Item | No. | Item | No. | Item | No | Item |
---|---|---|---|---|---|---|---|
1 | Bottom cover | 7 | O-ring | 13 | Big piston | 19 | Upper cover gasket |
2 | O-ring | 8 | Body | 14 | Big piston O-ring | 20 | Upper cover |
3 | O-ring | 9 | Gasket | 15 | Screw | 21 | Small piston |
4 | War ring | 10 | Spacer | 16 | Gasket | 22 | Small piston O-ring |
5 | O-ring | 11 | O-ring | 17 | Cover plate | 23 | Small piston sheath |
6 | Screw | 12 | Big piston sheath | 18 | Spool |