OMRON Counter - H7GP

English
ไทย

Counter - H7GP

DOWNLOAD PDF
Counter - H7GP
OMRON Counter - H7GP
Model Numbers
Specifications
Dimensions
Features

Model Numbers | Counter - H7GP

Total counter

<thcolspan="2">6-digit total counter
Supply voltage
Light grayBlack
100 to 240 VAC H7GP-C H7GP-CB
12 to 24 VDC H7GP-CD H7GP-CDB

Time counter

Supply voltage6-digit time counter
Light grayBlack
100 to 240 VAC H7GP-T H7GP-TB
12 to 24 VDC H7GP-TD H7GP-TDB

Specifications | Counter - H7GP

Ratings

Item6-digit total counter6-digit time counter
H7GP-CH7GP-CDH7GP-TH7GP-TD
Rated supply voltage 100 to 240 VAC
(50/60 Hz)
12 to 24 VDC *1 100 to 240 VAC
(50/60 Hz)
12 to 24 VDC *1
External power supply 50 mA at 12 VDC --- 50 mA at 12 VDC ---
Operating voltage range 85% to 110% of rated supply voltage
Power consumption 100 to 240 VAC: 6.5 VA max.
12 to 24 VDC: 0.6 W max.
Dimensions 48 x 24 x 80 mm (W x H x D)
Mounting method Flush mounting
External connections Screw terminals
Degree of protection Panel surface: IP66 with oil resistance and NEMA Type 4 (indoors).
Display 7-segment, negative transmissive LCD (with red backlight)
Digits 6 digits (8.5-mm-high characters)
Input mode Up (increment) Accumulative
Max. counting speeds 30 Hz or 5 kHz (selected via DIP switch) ---
Counting range 0 to 999999 ---
Time specification --- 0.1 to 99999.9 h/1 s to 99 h 59 min 59 s
(selected via DIP switch)
Timing accuracy --- ±100 ppm (-10°C to 55°C)
Memory backup EEP-ROM (overwrites: 200,000 times min.) that can store data for 20 years min.
InputInput signals Count, reset, and key protection *2 Start, reset, and key protection *2
Input method No-voltage input (NPN transistor input) or voltage input (PNP transistor input) (selected
via DIP switch)
Count, reset,
start
No-voltage input (NPN transistor input)
Short-circuit (ON) impedance: 1 kΩ max.
Short-circuit (ON) residual voltage:2 VDC max.
Open (OFF) impedance: 100 kΩ min.
Voltage input (PNP transistor input)
Short-circuit (ON) impedance: 1 kΩ max.
ON voltage: 9 to 24 VDC
OFF voltage: 5 VDC max.
Open (OFF) impedance: 100 kΩ min.
Key protection No-voltage input (NPN transistor input)
Short-circuit (ON) impedance: 1 kΩ max.
Short-circuit (ON) residual voltage:0.5 VDC max.
Open (OFF) impedance: 100 kΩ min.
Input
response
speed
Reset 20 or 1 ms (automatically switched
according to counting speed)
20 ms
Start --- 20 ms
Key protection Approx. 1 s Approx. 1 s
Reset system External and manual resets

*1. Contains 20% ripple (p-p) max.
*2. Only a non-voltage input (NPN transistor) is possible for the key protection input. The key protection input will be a non-voltage input even if the NPN/PNP input mode is set to PNP. Key protection is used to prohibit operating the Reset Key. The reset input terminals will still be functional.

Characteristics

Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-
carrying metal parts (AC model)
1,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-
carrying metal parts (DC model)
2,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals (AC model)
Impulse withstand
voltage
3 kV (between power terminals) (1 kV for 12-to-24-VDC models)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) (1.5
kV for 12-to-24-VDC models)
Noise immunity ±1.5 kV (between AC power terminals), ±480 V (between DC power terminals),
±480 V (between input terminals);
square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity Display: Malfunction: 8 kV, Destruction: 15 kV
DIP switch: Malfunction: 4 kV, Destruction: 8 kV
Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude, 2 hours each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude, 10 minutes each in three directions
Shock resistance Destruction: 294 m/s2 each in three directions
Malfunction: 196 m/s2 each in three directions
Ambient temperature Operating: -10°C to 55°C (with no icing)
Storage: -25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%
EMC (EMI) EN61326-1 (note 1.)
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS) EN61326-1 (note 1.)
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2); 8 kV air discharge (level 3)
Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz)
(level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to
EN61000-6-2)
Immunity Burst: EN61000-4-4: 2 kV power-line (level 3); 2 kV I/O signal-line (level 4)
Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2); 2 kV line to
ground (power and output lines) (level 3)
Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage)
Approved standards UL508 (note 2), CSA C22.2 No.14 (note 2), conforms to EN61010-1, VDE0106/P100
Case color Rear section: Gray smoke; Front section: 5Y7/1 (light gray) or N1.5 (black)
Weight Approx. 75 g
    Note:
  1. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
  2. UL508 and CAN/CSA-C22.2 No.14 certification conditions)
    • Power supply 100 to 240VAC types
      • Ambient temperature 30°C Single mounting
    • Power supply 12 to 24VDC types
      • Ambient temperature 40°C Single mounting

Dimensions | Counter - H7GP

H7GP-C
H7GP-T

H7GP Dimensions 2 H7GP-C_Dim

With Flush Mounting Bracket

H7GP Dimensions 2 H7GP-C_Dim

Panel Cutouts

Panel cutouts are as shown below (according to DIN43700).

H7GP Dimensions 2 H7GP-C_Dim

Note:The mounting panel thickness should be 1 to 6 mm.

Note:Water resistance will be lost if Counters are mounted side-by-side.

Note:The terminal screws are M3.5.
(Theeffective thread length is 6 mm.)

Note:When horizontally mounting Counters side-by-side, leave at least 50 mm between any two Counters.

Features | Counter - H7GP

IP66 with oil resistance and NEMA 4 Compact body Just change a switch setting for either an NPN or PNP input Complies with EMC standards (EN 61326) and CE Marking


Properties | Counter - H7GP

CounterH7CX-R
Power supply 100 – 240 Vac (50 – 60Hz)
24 Vac (50 – 60Hz)
10 – 24 Vdc
Max counting speed 30 Hz
Input method No-voltage (NPN) input/voltage (PNP) input
High (logic) level: 4.5 to 30 VDC, Low (logic) level: 0 to 2 VDC
Output Contact output: 3 A at 250 VAC/30 VDC
Reset system External
automatic reset
Dimensions
(W x L x H)
24 x 48 x 80
Weight (g) 75

Counter - H7GP

ดาวน์โหลดไฟล์ PDF
Counter - H7GP
OMRON Counter - H7GP

คุณสมบัติ | Counter - H7GP

เครื่องนับจำนวนตามที่ตั้งไว้ล่วงหน้า มีมาตรฐานการป้องกัน IP66( ป้องกันน้ำมัน) และ NEMA 4 ขนาดกะทัดรัด สามารถเปลี่ยน PNP กับ NPN อินพุทได้โดยปุ่มตั้งค่า มีการป้องกันสัญญาณรบกวน EN 61326


ข้อมูลจำเพาะ | Counter - H7GP

CounterH7BXOMRON Counter - H7GP
แหล่งจ่ายไฟ 100–240Vac (50-60 Hz)
24Vac (50-60Hz)
10-24Vdc
ความเร็วการนับสูงสุด 30 Hz
รูปแบบของอินพุต แบบ NPN และ PNP
รีเซต แบบต่อภายนอก
แบบอัตโนมัติ
ขนาด กว้าง 24 mm / ยาว 48 mm / ลึก 80 mm
น้ำหนัก 75 กรัม

ติดต่อแผนก Automation & Robots

ติดต่อ นิวแอนด์ไฮด์ ฝ่าย Automation
ดาว์นโหลด แคตตาล็อก, สเป้กแอร์แทค
Promotion-Big Sale
ติดต่อเรา
TICTechnology Instrument 
www.tic.co.th
tupackT.U Pack 
www.tupack.co.th
Your LiftYour Lift 
www.yourlift.co.th