OMRON Counter - H7CZ

English
ไทย

Counter - H7CZ

DOWNLOAD PDF
Counter - H7CZ
OMRON Counter - H7CZ
Model Numbers
Specifications
Dimensions
Features

Model Numbers | Counter - H7CZ

Note: The functions that are provided depend on the model. Check detailed specifications before ordering.

Accessories (Order Separately)

Soft Cover

Model
Y92A-48F1

Hard Cover

Model
Y92A-48

Flush Mounting Adapter

Model
Y92F-30

Waterproof Packing

Model
Y92S-29

Connection Sockets

ModelTypeRemarks
P2CF-08 Front-connecting Socket ---
P2CF-08-E Front-connecting Socket
(Finger-safe Type)
Round crimp terminals cannot be used on Finger-safe Sockets.
Use forked crimp terminals.
P3G-08 Back-connecting Sockets A Y92A-48G Terminal Cover can be used with the Socket to create a
finger-safe construction.

Terminal Covers for P3G-08 Back-connecting Socket

Model
Y92A-48G

Specifications | Counter - H7CZ

Ratings

ModelsH7CZ-L8H7CZ-L8D1
Configuration 1-stage preset counter
RatingsPower supply voltage *1 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz or 12 to 24 VDC
Operating voltage
fluctuation range
85% to 110% of rated supply voltage (12 to 24 VDC: 90% to 110%)
Power consumption Approx. 9.4 VA at 100 to 240 VAC,
Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC
Mounting method Flush mounting or surface mounting
External connections 8-pin socket
Degree of protection IEC IP66, UL508 Type 4X (indoors) for panel surface only and only when Y92S-
29 Waterproof Packing is used.
Input signals Count, Reset
CounterMaximum counting speed 30 Hz or 10 kHz (switchable) (ON/OFF ratio 1:1)
Input mode Increment, Decrement
Output mode N, F, C, R, K-1, P, Q, and A.
One-shot output time 0.01 to 99.99 s
Reset system External (minimum reset signal width: 1 ms or 20 ms, selectable), Manual, and
Automatic reset (internal according to C, R, P, and Q mode operation)
Prescaling function Yes (0.001 to 99.999)
Decimal point adjustment Yes (rightmost 3 digits)
Sensor waiting time 290 ms max. (Control output is turned OFF and no input is accepted during
sensor waiting time.)
Input method No-voltage inputs:
ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Control output 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load: 10 mA
at 5 VDC (failure level: P, reference value)
Display *2 LCD
Character height
Count value: 10 mm
Set value: 6 mm
Digits 6 digits
-99999 to 999999
(-5 digits to +6 digits)
Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature range -10 to 55°C (-10 to 50°C if Counters are mounted side by side) (with no
icing or condensation)
Storage temperature range -25 to 70°C (with no icing or condensation)
Operating humidity range 25% to 85%
Front panel color Light gray (5Y7/1)

*1. Do not use the output from an inverter as the power supply.The ripple must be 20% maximum for DC power.
*2. The display is lit only when the power is ON. Nothing is displayed when power is OFF.


Characteristics

Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying terminals and exposed non-
current-carrying metal parts, and between non-continuous contacts
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-
carrying metal parts
2,000 VAC, 50/60 Hz for 1 min between power supply and input circuit (1,000 VAC for
24 VAC/12 to 24 VDC)
1,000 VAC, 50/60 Hz for 1 min between control output, power supply, and input circuit
(2,000 VAC)
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
Impulse withstand voltage 3.0 kV between power terminals (1.0 kV for models with 24 VAC/12 to 24 VDC)
4.5 kV between current-carrying terminals and exposed non-current-carrying metal
parts (1.5 kV for models with 24 VAC/12 to 24 VDC)
Noise immunity ±1.5 kV between power terminals
±600 V between input terminals
Square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity Malfunction: 8 kV
Destruction: 15 kV
Vibration
resistance
Destruction 10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h each
Malfunction 10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min each
Shock
resistance
Destruction 300 m/s2 each in three directions
Malfunction 100 m/s2 each in three directions
Life expectancy Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, ambient temperature
condition: 23°C)*
Weight Approx. 100 g (Counter only)

* Refer to the Life-test Curve.


Life-test Curve (Reference Values)

Resistive load

H7CZ Specifications

Inductive load

H7CZ Specifications

A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both cases, a life of 100,000 operations can be expected.


Applicable Standards

Approved safety
standards
cULus (or cURus): UL508/CSA C22.2 No. 14 *1
EN 61010-1 (IEC 61010-1): Pollution degree 2/overvoltage category II
B300 PILOT DUTY
1/4 HP 120 VAC, 1/3 HP, 240 VAC, 3 A resistive load
VDE0106/P100 (finger protection)
EMC (EMI) EN61326-1 *2
Emission Enclosure: EN 55011 Group 1 class A
Emission AC mains: EN 55011 Group 1 class A
(EMS) EN61326-1 *2
Immunity ESD: EN 61000-4-2: 4 kV contact discharge; 8 kV air discharge
Immunity RF-interference: EN 61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz);
10 V/m (Pulse-modulated, 900 MHz ±5 MHz)
Immunity Conducted Disturbance: EN 61000-4-6: 10 V (0.15 to 80 MHz)
Immunity Burst: EN 61000-4-4: 2 kV power-line; 1 kV I/O signal-line
Immunity Surge: EN 61000-4-5: 1 kV line to lines (power and output lines);
2 kV line to ground (power and output lines)
Immunity Voltage Dip/Interruption: EN 61000-4-11: 0.5 cycle, 100% (rated voltage)

*1. The following safety standards apply to H7CZ.
cUL (Listing): Applicable when an OMRON P2CF(-E) Socket is used.
cUR (Recognition): Applicable when any other socket is used.
*2. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)


I/O Functions

Using as a Counter *1

InputsCount • Reads counting signals.
• Increment and decrement inputs accepted.
Reset • Resets present value and outputs.*2
• Counting cannot be performed during reset input.
• Reset indicator is lit while reset input is ON.
OutputsOUT Outputs signals according to the specified output mode when a set value is reached.

*1. For information on operation of I/O functions, refer to Catalog.
*2. In elapsed time mode, the present value returns to 0; in remaining time mode, the present value returns to the set value.

The following table shows the delay from when the reset signal is input until the output is turned OFF. (Reference values)

Minimum reset signal widthOutput delay time
1 ms 0.8 to 1.2 ms
20 ms 15 to 25 ms

Dimensions | Counter - H7CZ

Counters

H7CZ-L8/-L8D1 (Flush Mounting/Surface Mounting Models)

H7CZ Dimensions

Dimensions with Flush Mounting Adapter
H7CZ-L8/-L8D1 (Adapter and Waterproof Packing Ordered Separately)

H7CZ Dimensions

Panel Cutouts

Panel cutouts are as shown below. (according to DIN43700).

H7CZ Dimensions

Note:
1. The mounting panel thickness should be 1 to 5 mm.
2. To allow easier operation, it is recommended that Adapters be mounted so that the gap between sides with hooks is at least 15 mm (i.e., with the panel cutouts separated by at least 60 mm).
3. It is possible to horizontally mount Timers side by side. Attach the Flush Mounting Adapters so that the surfaces without hooks are on the sides of the Timers. If they are mounted side-by-side, water-resistance will be lost.

H7CZ Dimensions

Dimensions with Front Connecting Socket

H7CZ Dimensions

* These dimensions depend on the kind of DIN Track. (Reference value)

Features | Counter - H7CZ

Preset number counter Earlier counters have had limitations. In the wiring and can be damaged if the wiring is not correct. H7CZ eliminates these concerns


Properties | Counter - H7CZ

CounterH7CX-R
Power supply 100 – 240 Vac (50 – 60Hz)
24 Vac (50 – 60Hz)
10 – 24 Vdc
Max counting speed 30 Hz
Input method No-voltage (NPN) input
High (logic) level: 4.5 to 30 VDC, Low (logic) level: 0 to 2 VDC
Output Contact output: 3 A at 250 VAC/30 VDC
Reset system External
automatic reset
Output mode N, F, C, R, K-1, P, Q, and A.
Dimensions width 48 mm length 48 mm height 94.3 mm
Weight 100 g

Counter - H7CZ

ดาวน์โหลดไฟล์ PDF
Counter - H7CZ
OMRON Counter - H7CZ

คุณสมบัติ | Counter - H7CZ

เครื่องนับจำนวนตามที่ตั้งไว้ล่วงหน้า เคาน์เตอร์รุ่นก่อนหน้านี้มีจะมีข้อจำกัด ในการเดินสายและอาจจะเกิดความเสียหายได้ถ้าหากเดินสายไม่ถูกต้อง H7CZ ช่วยขจัดความกังวลเหล่านี้ออกไป


ข้อมูลทางเทคนิค | Counter - H7CZ

CounterH7CZ
แหล่งจ่ายไฟ 100–240Vac (50-60 Hz) / 24Vac (50-60Hz) / 10-24Vdc
ความเร็วการนับสูงสุด 30 Hz
รูปแบบของอินพุต แบบ NPN
เอาต์พุต เอาต์พุตแบบหน้าสัมผัส 3A 250Vac / 30Vdc
รีเซต แบบต่อภายนอก
แบบอัตโนมัติ
รูปแบบเอาต์พุต N, F, C, R, K-1, P, Q, and A
ขนาด กว้าง 48 mm / ยาว 48 mm / ลึก 94.3 mm