OMRON Safety Door Switches - D4NH

English
ไทย

Safety Door Switches - D4NH series

Download PDF
OMRON Safety Door Switches - D4NH
OMRON Safety Door Switches - D4NH series
Model Number
Specifications
Dimensions
Features

Model Number| Safety Door Switches - D4NH series

Switches

Consult with your OMRON representative when ordering any models that are not listed in this table.

ActuatorConduit outletBuilt-in switch mechanism
1NC/1NO
(Slow-action)
2NC
(Slow-action)
2NC/1NO
(Slow-action)
Shaft 1-conduit type Pg13.5 D4NH-1AAS D4NH-1BAS D4NH-1CAS
G1/2 D4NH-2AAS D4NH-2BAS D4NH-2CAS
M20 D4NH-4AAS D4NH-4BAS D4NH-4CAS
2-conduit type G1/2 D4NH-6AAS D4NH-6BAS D4NH-6CAS
M20 D4NH-8AAS D4NH-8BAS D4NH-8CAS
Arm lever 1-conduit type Pg13.5 D4NH-1ABC D4NH-1BBC D4NH-1CBC
G1/2 D4NH-2ABC D4NH-2BBC D4NH-2CBC
M20 D4NH-4ABC D4NH-4BBC D4NH-4CBC
2-conduit type G1/2 D4NH-6ABC D4NH-6BBC D4NH-6CBC
M20 D4NH-8ABC D4NH-8BBC D4NH-8CBC
ActuatorConduit outletBuilt-in switch mechanism
3NC
(Slow-action)
1NC/1NO MBB
(Slow-action)
2NC/1NO MBB
(Slow-action)
Shaft 1-conduit type Pg13.5 D4NH-1DAS D4NH-1EAS D4NH-1FAS
G1/2 D4NH-2DAS D4NH-2EAS D4NH-2FAS
M20 D4NH-4DAS D4NH-4EAS D4NH-4FAS
2-conduit type G1/2 D4NH-6DAS D4NH-6EAS D4NH-6FAS
M20 D4NH-8DAS D4NH-8EAS D4NH-8FAS
Arm lever 1-conduit type Pg13.5 D4NH-1DBC D4NH-1EBC D4NH-1FBC
G1/2 D4NH-2DBC D4NH-2EBC D4NH-2FBC
M20 D4NH-4DBC D4NH-4EBC D4NH-4FBC
2-conduit type G1/2 D4NH-6DBC D4NH-6EBC D4NH-6FBC
M20 D4NH-8DBC D4NH-8EBC D4NH-8FBC

Note: All models have slow-action contacts with certified direct opening mechanisms on NC contacts only.

Specifications | Safety Door Switches - D4NH series

Standards and EC Directives

Conforms to the following EC Directives:

• Machinery Directive
• Low Voltage Directive
• EN50047
• EN60204-1
• EN ISO 14119
• GS-ET-15

Certified Standards

Certification bodyStandardFile No.
TÜV SÜD EN60947-5-1 (certified direct opening) Consult your OMRON representative for details.
UL * UL508, CSA C22.2 No.14 E76675
CCC (CQC) GB/T 14048.5 Consult your OMRON representative for details.

* Certification for CSA C22.2 No. 14 is authorized by the UL mark.

Certified Standard Ratings

TÜV (EN60947-5-1)

Utilization categoryAC-15DC-13
Rated operating current (Ie) 3 A 0.27 A
Rated operating voltage (Ue) 240 V 250 V
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built
into the Switch.

UL/CSA (UL508, CSA C22.2 No. 14)

A300

Rated voltageCarry currentCurrent (A)Volt-amperes (VA)
MakeBreakMakeBreak
120 VAC 10 A 60 6 7,200 720
240 VAC 30 3

Q300

Rated voltageCarry currentCurrent (A)Volt-amperes (VA)
MakeBreakMakeBreak
125 VDC 2.5 A 0.55 0.55 69 69
250 VDC 0.27 0.27

Characteristics

Interlock type Type 1 (EN ISO 14119)
Coding level Uncoded (EN ISO 14119)
Degree of protection *1 IP67 (EN60947-5-1)
Durability *2Mechanical 1,000,000 operations min.
Electrical 500,000 operations min. (3 A resistive load at 250 VAC) *3
300,000 operations min. (10 A resistive load at 250 VAC)
Operating speed 2 to 360°/s
Operating frequency 30 operations/minute max.
Direct opening force *4 1 N·m min.
Direct opening travel *4 18° min.
Contact resistance 25 mΩ max.
Minimum applicable load *5 1 mA resistive load at 5 VDC (N-level reference value)
Rated insulation voltage (Ui) 300 V
Rated frequency 50/60 Hz
Protection against electric shock Class II (double insulation) 1501_sp_5_1
Pollution degree (operating environment) 3 (EN60947-5-1)
Impulse withstand
voltage (Uimp)
(EN60947-5-1)
Between terminals of same
polarity
2.5 kV
Between terminals of different
polarity
4 kV
Between each terminal and
non-current carrying metallic
parts
6 kV
Insulation resistance 100 MΩ min.
Contact gap 2 × 2 mm min.
Vibration resistanceMalfunction 10 to 55 Hz, 0.75 mm single amplitude
Shock resistanceDestruction 1,000 m/s2 min.
Malfunction 300 m/s2 min.
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional free air thermal current (Ith) 10 A (EN60947-5-1)
Ambient operating temperature -30 to 70°C (with no icing)
Ambient operating humidity 95% max.
Weight Approx. 87 g (D4NH-1AAS)
Approx. 97 g (D4NH-1ABC)

Note: 1. The above values are initial values.
2. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The
contact surfaces will become rough once they have been used and contact reliability for smaller loads may be
reduced.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing
properties are sufficient for the operating conditions and environment beforehand. Although the switch box is
protected from dust or water penetration, do not use the D4NH in places where foreign material such as dust, dirt,
oil, water, or chemicals may enter through the head. Otherwise, accelerated wear, Switch damage, or malfunctioning
may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details,
consult your OMRON representative.
*3. Do not pass the 3 A, 250 VAC load through more than 2 circuits.
*4. Be sure to provide this amount to ensure safety in operation.
*5. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is
possible with the actual load beforehand.

Dimensions | Safety Door Switches - D4NH series

Shaft Type with 1 Conduit
D4NH-1[]AS D4NH-2[]AS
D4NH-4[]AS

D4NH Dimensions 1

Shaft Type with 2 Conduits
D4NH-6[]AS D4NH-8[]AS

D4NH Dimensions 2

Arm Lever Type with 1 Conduit
D4NH-1[]BC D4NH-2[]BC
D4NH-4[]BC

D4NH Dimensions 3

Arm Lever Type with 2 Conduits
D4NH-6[]BC D4NH-8[]BC

D4NH Dimensions 4

Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Variation occurs in the simultaneity of contact opening/closing operations of 2NC, 2NC/1NO, and 3NC contacts.
Check contact operation.

Features | Safety Door Switches - D4NH series

  • Multi-contact, environment-friendly, next-generation safety-door switch
  • Shaft or arm lever actuator
  • Wide temperature range
  • Three contact models

Properties | Safety Door Switches - D4NH series

Safety Door SwitchesD4NH series
Max Actuation Frequency 30 operations / min
Max Actuation Speed 2 to 360°/ s
Weight Approx 87 g (D4NH-1AAS)
Approx 97 g D4NH-1ABC)
Built-in Switch 1 NO/1 NC, 2 NC, 2 NC/1 NO, 3 NC (Slow-action)
1 NC/1 NO , 2 NC/1 NO (MBB contact)
Degree of protection IP67
Dimensions (W x L x H) mm 82.5 x 31 x 60 (Shaft Type with 1 Conduit)
72.5 x 56 x 60 (Shaft Type with 2 Conduit)
153 x 31 x 38 (Arm Lever Type with 1 Conduit)
145 x 56 x 38 (Arm Lever Type with 2 Conduit)

Safety Door Switches - D4NH series

ดาวน์โหลดไฟล์ PDF
OMRON Safety Door Switches - D4NH
OMRON Safety Door Switches - D4NH series

คุณสมบัติ | Safety Door Switches - D4NH series

  • โมเดลแบบ 3 หน้าสัมผัส (2 NC/1 NO และ 3 NC) และโมเดล MBB (1 NC/NO และ 2 NC)
  • หน้าสัมผัสแบบคันโยกยื่นออกมา
  • ช่วงในการทนอุณหภูมิของอุปกรณ์กว้าง
  • โมเดล 3 หน้าสัมผัส

ข้อมูลจำเพาะ | Safety Door Switches - D4NH series

Safety Door SwitchesD4NH
ความถี่สูงสุดในการทำงาน 30 การประมวล / นาที
ความเร็วสูงสุดในการทำงาน 2 to 360° / วินาที
น้ำหนัก ประมาณ 87 กรัม (D4NH-1AAS)
ประมาณ 97 กรัม (D4NH-1ABC)
รูปแบบหน้าสัมผัส 1 NO/1 NC, 2 NC, 2 NC/1 NO, 3 NC (Slow-action)
1 NC/1 NO , 2 NC/1 NO (MBB contact)
มาตรฐานการป้องกัน IP67
ขนาด (W x L x H) mm 82.5 x 31 x 60 (Shaft Type with 1 Conduit)
72.5 x 56 x 60 (Shaft Type with 2 Conduit)
153 x 31 x 38 (Arm Lever Type with 1 Conduit)
145 x 56 x 38 (Arm Lever Type with 2 Conduit)

ติดต่อแผนก Automation & Robots

ติดต่อ นิวแอนด์ไฮด์ ฝ่าย Automation
ดาว์นโหลด แคตตาล็อก, สเป้กแอร์แทค
Promotion-Big Sale
ติดต่อเรา
TICTechnology Instrument 
www.tic.co.th
tupackT.U Pack 
www.tupack.co.th
Your LiftYour Lift 
www.yourlift.co.th