Insulation methodOperation indicatorZero cross functionApplicable output load *Rated input voltageModel
Photocoupler Yes (yellow) Yes 75 A, 100 to 240 VAC 5 to 24 VDC G3PH-2075B DC5-24
100 to 240 VAC G3PH-2075B AC100-240
150 A, 100 to 240 VAC 5 to 24 VDC G3PH-2150B DC5-24
100 to 240 VAC G3PH-2150B AC100-240
No 75 A, 100 to 240 VAC 5 to 24 VDC G3PH-2075BL DC5-24
150 A, 100 to 240 VAC 5 to 24 VDC G3PH-2150BL DC5-24
Yes 75 A, 180 to 480 VAC 5 to 24 VDC G3PH-5075B DC5-24
100 to 240 VAC G3PH-5075B AC100-240
150 A, 180 to 480 VAC 5 to 24 VDC G3PH-5150B DC5-24
100 to 240 VAC G3PH-5150B AC100-240
No 75 A, 180 to 480 VAC 5 to 24 VDC G3PH-5075BL DC5-24
150 A, 180 to 480 VAC 5 to 24 VDC G3PH-5150BL DC5-24

Note:The Thyristor Module is built in.
* The applicable output load depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on Catalog.

Options (Order Separately)

Thyristor Module

NameApplicable output load *Applicable modelsModel
Thyristor Module 75 A, 75 to 264 VAC G3PH-2075B(L) G32A-P2075
150 A, 75 to 264 VAC G3PH-2150B(L) G32A-P2150
75 A, 150 to 528 VAC G3PH-5075B(L) G32A-P5075
150 A, 150 to 528 VAC G3PH-5150B(L) G32A-P5150

* The applicable output load depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on Catalog.

Specifications | Solid-state Relay - G3PH

Ratings

Input (at an Ambient Temperature of 25 C)

Rated voltageOperating voltageImpedance
(input current)
Voltage level
Must operate voltageMust release voltage
5 to 24 VDC 4 to 30 VDC (5 mA max.) * 4 VDC max. 1.0 VDC min.
100 to 240 VAC 75 to 264 VAC 41 kΩ ±20% 75 VAC max. 20 VAC min.

* A constant-current circuit is used for the input current to the G3PH.

Output

ModelApplicable load
Rated load voltage Load voltage range Load current *Inrush current resistance
G3PH-2075B(L) 100 to 240 VAC 75 to 264 VAC 1 to 75 A (at 40°C) 800 A (60 Hz, 1 cycle)
G3PH-2150B(L) 100 to 240 VAC 75 to 264 VAC 1 to 150 A (at 40°C) 1,800 A (60 Hz, 1 cycle)
G3PH-5075B(L) 180 to 480 VAC 150 to 528 VAC 1 to 75 A (at 40°C) 800 A (60 Hz, 1 cycle)
G3PH-5150B(L) 180 to 480 VAC 150 to 528 VAC 1 to 150 A (at 40°C) 1,800 A (60 Hz, 1 cycle)

* The load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in
Engineering Data on Catalog.

Characteristics

ModelG3PH- 2075BG3PH- 2150BG3PH- 5075BG3PH- 5150BG3PH- 2075BLG3PH- 2150BLG3PH- 5075BLG3PH- 5150BL
Operate time 1/2 of load power source cycle + 1 ms max. for DC input 3/2 of load power source cycle + 1 ms max. for AC input 1 ms max.
Release time 1/2 of load power source cycle + 1 ms max. for DC input 3/2 of load power source cycle + 1 ms max. for AC input 1/2 of load power source cycle + 1 ms max.
Output ON voltage drop 1.6 V (RMS) max.
Leakage current 30 mA max. (at 240 VAC) 60 mA max. (at 480 VAC) 30 mA max. (at 240 VAC) 60 mA max. (at 480 VAC)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,500 VAC, 50/60 Hz for 1 min
Vibration resistance 10 to 55 to10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) Acceleration of 50 m/s2 for 50 min in X, Y and Z directions (10 sweeps of 5 min each = 50 min total)
Shock resistance 500 m/s2, 3 times in X, Y, and Z directions
Ambient storage temperature -30 to 100°C (with no icing or condensation)
Ambient operating temperature -30 to 80°C (with no icing or condensation)
Ambient operating humidity 45% to 85%
Weight Approx. 1.8 kg Approx. 3.0 kg Approx. 1.8 kg Approx. 3.0 kg Approx. 1.8 kg Approx. 3.0 kg Approx. 1.8 kg Approx. 3.0 kg

Dimensions | Solid-state Relay - G3PH

Solid State Relays

G3PH-2075B(L)
G3PH-5075B(L)

G3PH Dimensions 2

G3PH-2150B(L)
G3PH-5150B(L)

G3PH Dimensions 3

Features | Solid-state Relay - G3PH

  • RoHS compliant.
  • Models also available with no zero cross.
  • Replaceable power elements.
  • Conforms to cULus standards and EN standards (TÜV certification).

Properties | Solid-state Relay - G3PH

Solid-state RelayG3PH
Input Operating voltage 4-30 VDC / 75-264 VAC
Output Operating voltage 75-264 / 150-528 VAC
Load current 1-75 / 1-150 A
Inrush current resistance 800 / 1800 A
Weight (kg) 1.8 / 3
Size (W x L x H) mm 120/156 x 150/186 x 120/156

Solid-state Relay - G3PH

ดาวน์โหลดไฟล์ PDF
Solid-state Relay - G3PH
OMRON Solid-state Relay - G3PH

คุณสมบัติ | Solid-state Relay - G3PH

  • 75 หรือ 150 แอมป์, แรงดันไฟฟ้ากระแสสลับ 240 หรือ 480 V
  • มีโมเดลแบบ Zero-cross และ non zero-cross
  • เป็นไปตามมาตรฐาน cULus และ EU
  • ไฟแสดงสถานะภายในตัว
  • สอดคล้องกับมาตรฐานสิ่งแวดล้อม (RoHS)

ข้อมูลจำเพาะ | Solid-state Relay - G3PH

Solid-state RelayG3PH
พิกัดแรงดันไฟฟ้าอินพุต 4-30 VDC / 75-264 VAC
พิกัดแรงดันไฟฟ้าเอาต์พุต 75-264 / 150-528 VAC
พิกัดกระแสไฟฟ้าเอาต์พุต 1-75 / 1-150 A
กระแสกระชาก 800 / 1800 A
น้ำหนัก ประมาณ 1.8 / 3 กิโลกรัม
ขนาด (W x L x H) mm 120/156 x 150/186 x 120/156

ติดต่อแผนก Automation & Robots

ติดต่อ นิวแอนด์ไฮด์ ฝ่าย Automation
ดาว์นโหลด แคตตาล็อก, สเป้กแอร์แทค
Promotion-Big Sale
ติดต่อเรา
TICTechnology Instrument 
www.tic.co.th
tupackT.U Pack 
www.tupack.co.th
Your LiftYour Lift 
www.yourlift.co.th